{"id":451,"date":"2026-07-06T06:21:37","date_gmt":"2026-07-06T06:21:37","guid":{"rendered":"https:\/\/comphysics.com\/?page_id=451"},"modified":"2026-09-05T14:52:18","modified_gmt":"2026-09-05T05:52:18","slug":"cp-uv01","status":"publish","type":"page","link":"https:\/\/comphysics.com\/index.php\/cp-uv01\/","title":{"rendered":"CP-UV01 Battery-Free UV Visualization Device"},"content":{"rendered":"<article class=\"cp-knowledge-page\">\n<section class=\"cp-knowledge-hero\">\n<div>\n<p class=\"cp-eyebrow\">ComPhysics CP-UV01<\/p>\n<h1>Battery-free UV visualization for direct observation and relative comparison<\/h1>\n<p class=\"cp-intro\">The CP-UV01 is a passive optical UV indicator developed by ComPhysics. Suitable UVA\/UVB input produces a visible green response, allowing users to observe UV presence and compare relative transmission under controlled, repeatable conditions.<\/p>\n<div class=\"cp-knowledge-actions\"><a class=\"button\" href=\"https:\/\/comphysics.com\/index.php\/product\/comphysics-cp-uv01-complete-uv-visualization-kit-with-smartphone-adapter\/\">Buy the Complete Kit<\/a><a class=\"button button-outline\" href=\"https:\/\/comphysics.com\/wp-content\/uploads\/2026\/07\/CP-UV01_Datasheet_EN_R1.1.pdf\" target=\"_blank\" rel=\"noopener\">Read the datasheet<\/a><\/div>\n<\/p><\/div>\n<figure><img decoding=\"async\" src=\"https:\/\/comphysics.com\/wp-content\/uploads\/2026\/08\/01_Representative_Actual_Complete_Kit_v2.png\" alt=\"CP-UV01 Complete Kit with CP-UV01 body, smartphone adapter, and detachable light shield\"><\/figure>\n<\/section>\n<section>\n<h2>What the CP-UV01 is\u2014and what it is not<\/h2>\n<p>The CP-UV01 uses passive optical wavelength conversion. It does not contain an electronic UV sensor, display, or battery. The visible green response is useful for visual indication and relative comparison, such as comparing two windows or lenses under the same UV source and geometry.<\/p>\n<p><strong>It is not a calibrated UV radiometer.<\/strong> It does not report irradiance in W\/m\u00b2, UV Index, dose, or exposure limits, and must not replace certified medical, safety, occupational, or laboratory instruments.<\/p>\n<div class=\"cp-fact-grid\" role=\"list\">\n<div role=\"listitem\"><strong>Input<\/strong><span>Suitable UVA\/UVB radiation<\/span><\/div>\n<div role=\"listitem\"><strong>Visible response<\/strong><span>Green optical signal<\/span><\/div>\n<div role=\"listitem\"><strong>Power<\/strong><span>No battery in the device<\/span><\/div>\n<\/div>\n<\/section>\n<section class=\"cp-split-section\">\n<div>\n<p class=\"cp-eyebrow\">How it works<\/p>\n<h2>Convert an invisible UV response into visible light<\/h2>\n<p>When suitable ultraviolet radiation reaches the CP-UV01 conversion structure, part of that input is emitted as visible green light. Response strength depends on wavelength, intensity, distance, angle, ambient light, and the material being tested.<\/p>\n<p>For meaningful comparisons, keep those conditions as consistent as possible and compare the visible response rather than treating it as an absolute measurement.<\/p>\n<\/div>\n<figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/comphysics.com\/wp-content\/uploads\/2026\/08\/03_Visible_UV_Transmission.png\" alt=\"Diagram explaining visible UV transmission comparison with the CP-UV01\"><\/figure>\n<\/section>\n<section class=\"cp-split-section cp-split-reverse\">\n<div>\n<p class=\"cp-eyebrow\">Complete Kit<\/p>\n<h2>Observe directly or record with a smartphone<\/h2>\n<p>The Complete Kit combines the CP-UV01 body with the CP-UV01-SA smartphone adapter and a detachable light shield. The shield reduces ambient light near the viewing area; the adapter positions the device over a smartphone camera for recording and comparison with the free ComPhysics Green UV app.<\/p>\n<ul>\n<li>CP-UV01 body \u00d7 1<\/li>\n<li>CP-UV01-SA smartphone adapter \u00d7 1<\/li>\n<li>Detachable light shield \u00d7 1<\/li>\n<li>Smartphone not included<\/li>\n<\/ul>\n<\/div>\n<figure><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/comphysics.com\/wp-content\/uploads\/2026\/08\/02_CP-UV01_Product_Overview.png\" alt=\"CP-UV01 product overview and component identification\"><\/figure>\n<\/section>\n<section>\n<h2>Example comparisons<\/h2>\n<p>Typical demonstrations include relative UV response from different light sources and relative UV transmission through windows, sunglasses, lenses, films, and fabrics.<\/p>\n<figure id=\"cp-indoor-uv-en-r2\" style=\"max-width:960px;margin:24px auto;\"><video src=\"https:\/\/comphysics.com\/wp-content\/uploads\/2026\/09\/CP_UV01_Indoor_Cases_EN_R2_1920x1440.mp4\" poster=\"https:\/\/comphysics.com\/wp-content\/uploads\/2026\/09\/poster.png\" width=\"1920\" height=\"1440\" controls playsinline preload=\"metadata\" style=\"display:block;width:100%;height:auto;aspect-ratio:4\/3;object-fit:contain;\" aria-label=\"Observe and record UV in your space\">Your browser does not support HTML5 video.<\/video><figcaption>Observe and record UV in your space.<\/figcaption><\/figure>\n<\/section>\n<section class=\"cp-downloads\">\n<h2>Documentation and apps<\/h2>\n<div><a class=\"button\" href=\"https:\/\/comphysics.com\/wp-content\/uploads\/2026\/07\/CP-UV01_Datasheet_EN_R1.1.pdf\" target=\"_blank\" rel=\"noopener\">English datasheet<\/a><a class=\"button button-outline\" href=\"https:\/\/comphysics.com\/wp-content\/uploads\/2026\/07\/CP-UV01_Datasheet_KR_R1.1.pdf\" target=\"_blank\" rel=\"noopener\">Korean datasheet<\/a><a class=\"button button-outline\" href=\"https:\/\/comphysics.com\/wp-content\/uploads\/2026\/07\/CP-UV01_Dimensional_Drawing_EN_R1.1.pdf\" target=\"_blank\" rel=\"noopener\">English drawing<\/a><a class=\"button button-outline\" href=\"https:\/\/comphysics.com\/wp-content\/uploads\/2026\/07\/CP-UV01_Dimensional_Drawing_KR_R1.1.pdf\" target=\"_blank\" rel=\"noopener\">Korean drawing<\/a><\/div>\n<p>ComPhysics Green UV: <a href=\"https:\/\/play.google.com\/store\/apps\/details?id=comphysics.greenuv\" target=\"_blank\" rel=\"noopener\">Google Play<\/a> \u00b7 <a href=\"https:\/\/apps.apple.com\/app\/id6794469621\" target=\"_blank\" rel=\"noopener\">Apple App Store<\/a><\/p>\n<\/section>\n<section class=\"cp-faq\" aria-labelledby=\"cp-knowledge-faq-title\">\n<h2 id=\"cp-knowledge-faq-title\">CP-UV01 questions and answers<\/h2>\n<details>\n<summary>Can CP-UV01 respond to UVA and UVB?<\/summary>\n<p>The device can produce a visible response to suitable UVA\/UVB input. Response varies with wavelength and intensity, so it should be used for indication and controlled relative comparison rather than absolute spectral measurement.<\/p>\n<\/details>\n<details>\n<summary>Can it compare UV-blocking materials?<\/summary>\n<p>Yes. Windows, lenses, films, and fabrics can be compared when the same source, distance, angle, ambient lighting, and viewing or camera settings are maintained.<\/p>\n<\/details>\n<details>\n<summary>Do I need the smartphone app?<\/summary>\n<p>No. The green response can be observed directly. The optional free app helps record and compare the response with a compatible smartphone camera.<\/p>\n<\/details>\n<details>\n<summary>Who develops and supplies the CP-UV01?<\/summary>\n<p>ComPhysics develops and supplies the CP-UV01 and its supporting software. International online orders are dispatched from the Republic of Korea, with destination-specific options shown in the cart.<\/p>\n<\/details>\n<\/section>\n<\/article>\n","protected":false},"excerpt":{"rendered":"<p>A battery-free optical UV indicator that converts suitable UVA\/UVB input into a visible green response for direct observation and relative comparison.<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-451","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/comphysics.com\/index.php\/wp-json\/wp\/v2\/pages\/451","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/comphysics.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/comphysics.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/comphysics.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/comphysics.com\/index.php\/wp-json\/wp\/v2\/comments?post=451"}],"version-history":[{"count":27,"href":"https:\/\/comphysics.com\/index.php\/wp-json\/wp\/v2\/pages\/451\/revisions"}],"predecessor-version":[{"id":709,"href":"https:\/\/comphysics.com\/index.php\/wp-json\/wp\/v2\/pages\/451\/revisions\/709"}],"wp:attachment":[{"href":"https:\/\/comphysics.com\/index.php\/wp-json\/wp\/v2\/media?parent=451"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}